<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-21 21-03-19
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 70 dBuV Classic
Pilot RDS Phase Difference
6.7 kHz 2.8 kHz -88 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 66 kHz 19080 0,0052
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,4 dBr 3,02 dBr 4,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Pekka Kuusisto (viulu), Raija Kerppo (piano) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 66 kHz MIN: 8 kHz % above 76 kHz: 0,0052 Acquired: 2025/02/21 21.02.15 Total samples: 19080 Equivalent time: 0:15:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 4,3 dBr MIN: 1,4 dBr AVE: 3,02 dBr % above 12,2 dBr: 0,0 Last value: 1,4 dBr (2025/02/21 21.02.14) 20.48 20.50 20.52 20.54 20.56 20.58 21.00 21.02 0 2 4 Pm [dBr]